General 


The Summacut ethernet module provides a web page to configure the module. 

This web page can be accessed by typing the IP address in your favorite browser. 

You will be requested to enter a user name and password. 





Default user name is ‘admin’ and default password is ‘admin’.

  

Ethernet communication issues 


When you are facing Ethernet communication issues, changing some settings could help solving them. Please do not change any settings that are not mentioned here! 

Pagina-einde 


“TTL1” page: “PRINT” option 

By default the “PRINT” option is disabled, which means that 8 clients are allowed to listen to the same socket at the same time. All clients get the same data. 
As we use bidirectional communication, this could cause issues when multiple clients send data to the Summacut. 

It is advised to enable the “PRINT” option to avoid this. 




Please restart the module as requested. 



Misc Config” page: “Reset Timeout” 

When no data is seen on TCP during  this time, the ethernet module will reset. This reset takes about 4s. After this reset the ethernet connection becomes available again, but any previous connection is closed.  


It is advised to set the “Reset Timeout” to 0, to avoid the module from executing a reset automatically.





Please restart the module as requested.